Compressed Air Consumption
Of Nex Flow Air Amplifiers or Air Movers
Air Movers/Air Amplifiers - Compressed Air Consumption:
(Based on gap of 0.002” (.05mm)
Compressed Air Consumption in SCFM (SLPM)
Inlet Pressure |
AM10 |
AM20 |
AM40 |
AM75 |
AM125 |
20 PSIG (1.4 BAR) |
2.2 (62.3) |
4.3 (121.8) |
8.0 (226.5) |
16.5 (467.2) |
65.0 (1840.6) |
40 PSIG (2.8 BAR) |
3.4 (96.3) |
6.1 (172.7) |
11.3 (320.0) |
23.2 (657.0) |
90.0 (2548.5) |
60 PSIG (4.1 BAR) |
4.3 (121.8) |
7.5 (212.4) |
15.0 (424.8) |
29.7 (841.0) |
119.5 (3383.9) |
80 PSIG (5.5 BAR) |
4.9 (138.8) |
9.3 (263.3) |
19.3 (546.5) |
37.0 (1047.7) |
137.5 (3893.6) |
100 PSIG (6.9 BAR) |
5.8 (164.2) |
11.0 (311.5) |
25.1 (710.8) |
44.0 (1245.9) |
150.0 (4247.5) |
120 PSIG (8.4 BAR) |
6.1 (172.7) |
11.8 (334.1) |
26.0 (736.2) |
47.0 (1330.9) |
152.0 (4304.2) |
Air Movers/Air Amplifiers - Ducting:
Both the inlet (vacuum intake) and discharge ends of the unit may be ducted for light material and fume conveying applications. Care must be taken to avoid unnecessary restrictions that will cause back pressure or suction resistance that will reduce performance levels. Keep back pressure and resistance to under 2" of water column.